Model no | EM231 Dual weighing module 50Hz, 0.02% FS accuracy | |
Article No | H7 231-2MH22-0XA0 | |
Description | The 200 series weighing expansion module is used to detect weighing sensor signals with sensitivity of 1mV/V, 2mV/V, or 4mV/V, and can be connected to two signals |
Conventional | Dimensions WxHxD(mm) | 71.2×80×62 |
Power dissipatio | 2W | |
Available current(SM bus) | 50mA | |
Available current(Sensor power 24V) | 120mA,max |
Technical data | Supply voltage | 20.4-28.8VDC |
Impulse current | 2A at 28.8VDC | |
Insurance (non replaceable) | 1A, 60V slow fuse | |
Isolation (on-site and logical) | isolate | |
Isolation (on-site and 24V) | isolate |
Sensor connection | Number of channels | 2 |
Weight Value Data Format | word | |
internal resolution | 65535(16bit) | |
connect | Full bridge strain gauge using 4-wire or 6-wire technology | |
Full scale error limit (temperature 20℃±10℃) | ≤0.02% | |
Linear error | ≤0.01%FS | |
Temperature coefficient of sensitivity | ≤±20ppm/Kv.E | |
Zero temperature coefficient | ≤±0.1uV/K | |
Temperature coefficient of sensitivity | 1mV/V;2mV/V;4mV/V | |
Sampling frequency | 50Hz | |
The limiting frequency of the low-pass filter | 0.05Hz、0.1Hz、0.2Hz、0.5Hz、1Hz、2Hz、5Hz、50Hz | |
Average filter | 0~255 | |
Distance to load cell | Maximum 500 meters | |
Load cell power supply voltage | Typical DC 6V | |
Load cell power supply current | Maximum 150mA | |
Allowable resistance value of load cell (no explosion-proof interface) | >40Ω,<4010Ω | |
Allowable resistance value of load cell (with explosion-proof interface) | >87Ω,<4010Ω | |
Common-mode suppression | >120dB@120VAC | |
Common-mode suppression CMRR@50/60Hz | Typical 80dB |
Interference suppression | Noise suppression | 85dB@50Hz/60Hz |
Insulation | 500V DC |
LED diagnosis | 24V diagnosis | On: 24VDC power supply normal, Off: No 24VDC power supply |
Cable break diagnosis | Flashing: sensor disconnected, off: no error |