Model no | cpu224s 14DI/10DO RLY | |
Article No | H7 214-1BD11-0XB8 | |
Description | Economical CPU224s, relay |
Conventional | Dimensions WxHxD(mm) | 120.5 x 80 x 62 |
weight(g) | 400 | |
Power dissipatio | 5W | |
Available current(SM bus) | 660mA | |
Available current(Sensor power 24V) | 400mA |
CPU specification | program storage (kb) | 16384 |
Data storage(kb) | 10240 | |
Data preservatio | All variables 20 years, Real-time clock 100 hours typical (70 hours minimum, 40 ℃) |
Ontology integrated I/O | Digital value | 14AI/10AO |
Analog value | none | |
Maximum local I/O digital quantity | 256(128I/128Q) | |
Maximum local I/O analog quantity | 64(32AI/32AQ) | |
Maximum number of I/O module extensions | 4 | |
High speed counter (total) | none | |
Uniphase | none | |
Orthogonal phas | none | |
Pulse output | / | |
timer | 256 | |
1ms | 4 | |
10ms | 16 | |
100ms | 236 | |
Counter count | 256 | |
Bit memory(M) | 256 | |
Time break | Two in total, have a resolution of 1ms | |
Edge break | Four rising edges and four falling edges | |
Clock | built-in |
Performance | Booleans’operation time | 0.15uS |
Floating point operation time | 100uS |
Communication | Communication interface | 2 RS485 |
Baud | PPI/MPI | 9.6、19.2、187.5Kbps |
free port | 1.2-115.2Kbps | |
Maximum number of sites | 32 stations per segment, 126 stations per network | |
Maximum number of primary stations | 32 | |
Point-to-point mode (PPI main station) | yes(NETR/NETW) | |
MPI connection | 4 in total, 2 reserved (1PG/1OP) |
Maximum cable length per section | Isolation relay | The maximum length at 38.4Kbps Baud is 1200m, and the maximum length at 187.5Kbps is 1000m |
Unisolated repeater | 50m |
Power supply | Voltage range | 85-264VAC(47-63Hz) |
Input current | 220VAC:25mA(CPU) | |
Impulse current | 264VAC;20A | |
Sensor voltage | 20.4-28.8VDC |
Isolation | Power input and logic | 1500VAC,1min |
Sensor power and logic | No isolation |
Input specification | Input points | 14 |
Input type | Leakage type/source type | |
Maximum continuous allowable voltage | 30VDC | |
Surge voltage | 35VDC,0.5S | |
Logic 1 signal | 15VDC,2.5mA | |
Logic 0 signal | 15VDC,1mA | |
Photoelectric isolation(Field side and Logic side) | 500VAC,1min |
Output specification | Output points | 10 |
Output type | relay | |
Voltage range | 5-30VDC or 5-250VAC | |
Surge voltage | 5A,4S@10% Duty cycle | |
Rated current per point (maximum) | 2A | |
Switching frequency (maximum) | 1Hz |
Delayed | Maximum connection delay | Max 10mS |
Disconnect delay | Max 10mS | |
Photoelectric isolation(Field side and Logic side) | 1500VAC,1min |
Contact endurance | non-loaded | 10000000 |
Rated load | 100000 |